No agent touches operational technology without a person saying yes.
The oil and gas OT pack holds every agent write to PLCs, SCADA and setpoints for an engineer, keeps safety systems out of every agent's reach and keeps test agents on simulators.
Oil and gas (OT)
| Policy | Decision | Mode |
|---|---|---|
| A person approves every OT write | Approval | Enforce |
| Only designated agents write to OT | Deny | Enforce |
| Never change safety systems | Deny | Enforce |
| Approve remote access into OT | Approval | Enforce |
| Keep test agents off live OT | Deny | Enforce |
- Tool
- scada.write_setpoint
- Change
- Discharge 1,180 psi
- Requested
- 3 min ago
In OT, a wrong action is a safety event, not a bug.
Writes to live plant
An agent that can change a setpoint or open a valve acts on physical equipment, not on data.
Safety systems
Shutdown systems and interlocks must never be bypassed or reset by software that guesses.
Remote access
Agents that open VPN, RDP or vendor sessions into OT create new paths across your perimeter.
The guidance behind the OT pack
The rules and guidance that shape how AI is controlled in energy and critical infrastructure, each linked to its official source.
- AI in OT principlesCISA, NSA, FBI and international partnersJoint guidance on integrating AI into OT, with a person in the loop for active control. (official source, opens in a new tab)
- ISA/IEC 62443ISA and IECSecurity for industrial automation and control systems, including zones, conduits and use control. (official source, opens in a new tab)
- NIST SP 800-82 Rev. 3National Institute of Standards and TechnologyGuide to operational technology security: architecture, access and safety considerations. (official source, opens in a new tab)
- NERC CIP-005-7North American Electric Reliability CorporationElectronic security perimeters and remote access management for bulk electric systems. (official source, opens in a new tab)
- NERC CIP-010-4North American Electric Reliability CorporationConfiguration change management and vulnerability assessments for bulk electric systems. (official source, opens in a new tab)
- TSA Security Directive Pipeline-2021-02GTransportation Security AdministrationCybersecurity measures for designated pipelines, including segmentation and access control. (official source, opens in a new tab)
Clovie maps its controls to these texts to help your teams; it is not legal advice, and using Clovie does not on its own make an organization compliant with any of them.
Controls in the oil and gas OT pack
6 controls, each a policy you install from the Policy Hub. Every one starts in monitor mode and changes nothing until you promote it after a simulation on your own traffic.
Oil and gas (OT)
Five policies for operators of OT, used with the action governance pack for tool access.
- A person approves
Approve every OT write
Any write to PLCs, SCADA, setpoints, valves or pumps needs an approver; only clear reads go through.
Oil and gas (OT) pack · mapped to CISA AI in OT, principle 4 - Blocked
Only designated agents write
Agents without the ot:write permission cannot write to OT at all, even with an approval.
Oil and gas (OT) pack · mapped to ISA/IEC 62443-3-3, FR 2 - Blocked
Never change safety systems
No agent can change, bypass, reset or trip safety instrumented systems, shutdowns or interlocks.
Oil and gas (OT) pack · mapped to CISA AI in OT, principle 4.2 - A person approves
Approve remote access
A person approves before an agent opens VPN, RDP, SSH or vendor remote access into OT.
Oil and gas (OT) pack · mapped to NERC CIP-005-7, R2 - Blocked
Test agents off live OT
Agents that are not in production can use only simulator, digital twin or lab OT tools.
Oil and gas (OT) pack · mapped to ISA/IEC 62443-3-2, zones - Blocked
Tools only for their teams
An agent can use an MCP server only when it is registered and open to the agent's team; others are denied.
Agent action governance pack
How an agent's write to OT is governed.
On site, next to the plant
Install Clovie on premises or air-gapped, inside the zones your OT security team defines. Nothing calls home.
- SaaS
- Customer VPC
- On-premises
- Air-gapped
Inside your zones
Run the gateway in the zone and conduit your architecture allows, close to the agents it governs.
Safe by default
An unknown tool verb counts as a write, so a naming mistake falls on the side of asking a person.
Simulators first
Tag simulators and digital twins, and let test agents learn there long before they see live plant.
Controls mapped to the frameworks you answer to
- NIST AI RMF: NIST AI Risk Management Framework
- ISO/IEC 42001: ISO/IEC 42001 AI management system
- OWASP Top 10: OWASP Top 10 for LLM applications and agentic AI
- EU AI Act: EU Artificial Intelligence Act
Questions
Do the OT policies block anything when installed?
No. Every policy installs in monitor mode, records what it would have done, and changes nothing until you promote it. Promote these policies to enforce before any agent can reach live OT.
How does Clovie know a tool call is a write?
Any OT tool call whose verb is not a clear read, such as get, read, list or monitor, counts as a write. Tag read-only tools whose names don't start with a read verb so they pass without approval.
Does this apply to electric utilities?
The controls work for any operator of OT. The NERC CIP references apply only to Bulk Electric System cyber systems, and the TSA directive only to designated pipelines; check which apply to you.
Can we run it with no connection to the internet?
Yes. On-premises and air-gapped installs check the licence offline, use models you host and keep the audit log on site.
See the OT pack on your own agents.
We'll run the controls on your own agents in monitor mode and show what they would have held and blocked.